{"product_id":"victron-lynx-shunt-ve-can-1000a","title":"Victron Energy Lynx Shunt VE.Can 1000A Battery Monitor","description":"\u003cp data-start=\"59\" data-end=\"377\"\u003eThe \u003cstrong data-start=\"63\" data-end=\"99\"\u003eVictron Energy Lynx Shunt VE.Can\u003c\/strong\u003e is an intelligent \u003cstrong data-start=\"118\" data-end=\"163\"\u003e1000A battery shunt and monitoring module\u003c\/strong\u003e designed for use within the modular Victron Lynx DC distribution system. It combines positive and negative busbars, accurate battery monitoring and a holder for the main system fuse in one neat, professional unit.\u003c\/p\u003e\n\u003cp data-start=\"379\" data-end=\"707\"\u003eIdeal for \u003cstrong data-start=\"389\" data-end=\"470\"\u003ecampervans, motorhomes, boats, commercial vehicles and off-grid power systems\u003c\/strong\u003e, the Lynx Shunt measures the current flowing into and out of the battery bank. It uses this information to calculate important battery data, including state of charge, voltage, current, consumed amp-hours and remaining battery capacity.\u003c\/p\u003e\n\u003cp data-start=\"709\" data-end=\"1053\"\u003eThe Lynx Shunt communicates through \u003cstrong data-start=\"745\" data-end=\"755\"\u003eVE.Can\u003c\/strong\u003e and is designed to be connected to a compatible \u003cstrong data-start=\"804\" data-end=\"825\"\u003eVictron GX device\u003c\/strong\u003e, such as a Cerbo GX. Battery information can then be viewed locally through a GX display or remotely through the Victron Remote Management portal when the system has an internet connection. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1055\" data-end=\"1266\"\u003eAs part of the Victron Lynx system, the shunt connects neatly alongside compatible modules such as the \u003cstrong data-start=\"1158\" data-end=\"1175\"\u003eLynx Power In\u003c\/strong\u003e and \u003cstrong data-start=\"1180\" data-end=\"1200\"\u003eLynx Distributor\u003c\/strong\u003e, helping create a tidy and scalable high-current DC installation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"1268\" data-end=\"1284\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1286\" data-end=\"1933\"\u003e\n\u003cli data-section-id=\"1ffogss\" data-start=\"1286\" data-end=\"1332\"\u003eGenuine \u003cstrong data-start=\"1296\" data-end=\"1332\"\u003eVictron Energy Lynx Shunt VE.Can\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kkpis2\" data-start=\"1333\" data-end=\"1381\"\u003eIntelligent \u003cstrong data-start=\"1347\" data-end=\"1381\"\u003e1000A continuous-current shunt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mlvih1\" data-start=\"1382\" data-end=\"1408\"\u003eBuilt-in battery monitor\u003c\/li\u003e\n\u003cli data-section-id=\"1qqjfk6\" data-start=\"1409\" data-end=\"1464\"\u003eMeasures battery voltage, current and state of charge\u003c\/li\u003e\n\u003cli data-section-id=\"1l8xdf4\" data-start=\"1465\" data-end=\"1523\"\u003eTracks consumed amp-hours and remaining battery capacity\u003c\/li\u003e\n\u003cli data-section-id=\"10m87q1\" data-start=\"1524\" data-end=\"1580\"\u003ePositive and negative busbars integrated into the unit\u003c\/li\u003e\n\u003cli data-section-id=\"7kschg\" data-start=\"1581\" data-end=\"1625\"\u003eBuilt-in position for the main system fuse\u003c\/li\u003e\n\u003cli data-section-id=\"1r9twy4\" data-start=\"1626\" data-end=\"1682\"\u003eCommunicates with compatible GX devices through VE.Can\u003c\/li\u003e\n\u003cli data-section-id=\"1dnz31o\" data-start=\"1683\" data-end=\"1722\"\u003eSuitable for 12V, 24V and 48V systems\u003c\/li\u003e\n\u003cli data-section-id=\"10pmrf8\" data-start=\"1723\" data-end=\"1793\"\u003eDesigned for use within the modular Victron Lynx distribution system\u003c\/li\u003e\n\u003cli data-section-id=\"1m7npup\" data-start=\"1794\" data-end=\"1837\"\u003ePotential-free programmable alarm contact\u003c\/li\u003e\n\u003cli data-section-id=\"10lt1qb\" data-start=\"1838\" data-end=\"1905\"\u003eIdeal for high-current leisure, marine and off-grid installations\u003c\/li\u003e\n\u003cli data-section-id=\"r6mgte\" data-start=\"1906\" data-end=\"1933\"\u003eMain fuse sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"fcq80n\" data-start=\"1935\" data-end=\"1956\"\u003eTechnical Details\u003c\/h3\u003e\n\u003cul data-start=\"1958\" data-end=\"2339\"\u003e\n\u003cli data-section-id=\"5npkt8\" data-start=\"1958\" data-end=\"1992\"\u003e\n\u003cstrong data-start=\"1960\" data-end=\"1977\"\u003eManufacturer:\u003c\/strong\u003e Victron Energy\u003c\/li\u003e\n\u003cli data-section-id=\"956p6n\" data-start=\"1993\" data-end=\"2025\"\u003e\n\u003cstrong data-start=\"1995\" data-end=\"2007\"\u003eProduct:\u003c\/strong\u003e Lynx Shunt VE.Can\u003c\/li\u003e\n\u003cli data-section-id=\"u2jw9s\" data-start=\"2026\" data-end=\"2062\"\u003e\n\u003cstrong data-start=\"2028\" data-end=\"2053\"\u003eSupply voltage range:\u003c\/strong\u003e 9–70V DC\u003c\/li\u003e\n\u003cli data-section-id=\"h5khv4\" data-start=\"2063\" data-end=\"2112\"\u003e\n\u003cstrong data-start=\"2065\" data-end=\"2095\"\u003eSupported system voltages:\u003c\/strong\u003e 12V, 24V and 48V\u003c\/li\u003e\n\u003cli data-section-id=\"177p4xi\" data-start=\"2113\" data-end=\"2154\"\u003e\n\u003cstrong data-start=\"2115\" data-end=\"2145\"\u003eContinuous current rating:\u003c\/strong\u003e 1000A DC\u003c\/li\u003e\n\u003cli data-section-id=\"1qnvj37\" data-start=\"2155\" data-end=\"2182\"\u003e\n\u003cstrong data-start=\"2157\" data-end=\"2175\"\u003eCommunication:\u003c\/strong\u003e VE.Can\u003c\/li\u003e\n\u003cli data-section-id=\"6ysbbe\" data-start=\"2183\" data-end=\"2227\"\u003e\n\u003cstrong data-start=\"2185\" data-end=\"2203\"\u003eAlarm contact:\u003c\/strong\u003e 3A at 30V DC or 250V AC\u003c\/li\u003e\n\u003cli data-section-id=\"nk9y9g\" data-start=\"2228\" data-end=\"2293\"\u003e\n\u003cstrong data-start=\"2230\" data-end=\"2246\"\u003eSystem type:\u003c\/strong\u003e Modular DC distribution and battery monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1k5a7ga\" data-start=\"2294\" data-end=\"2339\"\u003e\n\u003cstrong data-start=\"2296\" data-end=\"2310\"\u003eMain fuse:\u003c\/strong\u003e Required and sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2341\" data-end=\"2482\"\u003eVictron specifies a continuous current rating of 1000A and compatibility with 12V, 24V and 48V systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"q8c01p\" data-start=\"2484\" data-end=\"2507\"\u003eM8 and M10 Versions\u003c\/h3\u003e\n\u003cp data-start=\"2509\" data-end=\"2686\"\u003eThe Lynx Shunt VE.Can is available in \u003cstrong data-start=\"2547\" data-end=\"2570\"\u003eM8 and M10 versions\u003c\/strong\u003e. The correct version should be selected to match the connection size used by the other modules in your Lynx system.\u003c\/p\u003e\n\u003cul data-start=\"2688\" data-end=\"2805\"\u003e\n\u003cli data-section-id=\"hefslh\" data-start=\"2688\" data-end=\"2745\"\u003eThe \u003cstrong data-start=\"2694\" data-end=\"2706\"\u003eM8 model\u003c\/strong\u003e is designed to accommodate a CNN fuse.\u003c\/li\u003e\n\u003cli data-section-id=\"haz40c\" data-start=\"2746\" data-end=\"2805\"\u003eThe \u003cstrong data-start=\"2752\" data-end=\"2765\"\u003eM10 model\u003c\/strong\u003e can accommodate CNN, ANL or Mega fuses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2807\" data-end=\"2953\"\u003eThe required main fuse is not included and must be selected to suit the system design and connected cabling. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1qmgibc\" data-start=\"2955\" data-end=\"2968\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul data-start=\"2970\" data-end=\"3214\"\u003e\n\u003cli data-section-id=\"1krmnce\" data-start=\"2970\" data-end=\"3014\"\u003eCampervan and motorhome electrical systems\u003c\/li\u003e\n\u003cli data-section-id=\"xnegco\" data-start=\"3015\" data-end=\"3046\"\u003eMarine and boat installations\u003c\/li\u003e\n\u003cli data-section-id=\"10q5x6y\" data-start=\"3047\" data-end=\"3071\"\u003eOff-grid battery banks\u003c\/li\u003e\n\u003cli data-section-id=\"1u9qaw7\" data-start=\"3072\" data-end=\"3101\"\u003eHigh-power inverter systems\u003c\/li\u003e\n\u003cli data-section-id=\"169aulj\" data-start=\"3102\" data-end=\"3134\"\u003eCommercial vehicle conversions\u003c\/li\u003e\n\u003cli data-section-id=\"13xhxmj\" data-start=\"3135\" data-end=\"3173\"\u003eVictron Lynx DC distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"88l1ci\" data-start=\"3174\" data-end=\"3214\"\u003e12V, 24V and 48V battery installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ambogg\" data-start=\"3216\" data-end=\"3254\"\u003eImportant Installation Information\u003c\/h3\u003e\n\u003cp data-start=\"3256\" data-end=\"3610\"\u003eFor accurate battery monitoring, the battery bank must be connected on the battery side of the Lynx Shunt, with all chargers and electrical loads connected on the system side. This ensures that all current entering and leaving the battery passes through the shunt and is included in its state-of-charge calculations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3612\" data-end=\"3838\"\u003eThe \u003cstrong data-start=\"3616\" data-end=\"3645\"\u003eVictron Lynx Shunt VE.Can\u003c\/strong\u003e is an excellent choice for professional electrical installations requiring high-current DC distribution, main fuse protection and detailed battery monitoring in one compact, integrated module.\u003c\/p\u003e","brand":"Nomadic Leisure","offers":[{"title":"Default Title","offer_id":57273039389045,"sku":"LYN040102110","price":275.0,"currency_code":"GBP","in_stock":true}],"url":"https:\/\/nomadicleisure.co.uk\/products\/victron-lynx-shunt-ve-can-1000a","provider":"Nomadic Leisure","version":"1.0","type":"link"}